KPM60F Low-voltage Motor Protection Controller

The KPM60F split-type motor protection controller is suitable for industrial applications to protect motors. It significantly simplifies the secondary control and protection circuits of the motor by providing protection, control, measurement, and fault management functions. It offers comprehensive protection and control measures, and its network-based communication with various buses enables networked management of the motor.

KPM60F adopts a modular design, which is small and compact, and easy to install. It can be used in low-voltage control terminal cabinets and 1/2 module or larger drawer cabinets for DIN rail installation, and is suitable for applications in coal mines, petrochemical plants, metallurgy, and power industries.

Features

KPM60F Low-voltage Motor Protection Controller Model Selection

KPM60 Low-voltage Motor Protection Controller Model

KPM60F Low-voltage Motor Protection Controller Technical Tables

Working power source Operating Voltage 85-305VAC/70-430VDC
Rated power < 5VA
Input voltage Rated voltage 380V-660V
Frequency range 45~65Hz
Input current Rated current 5A, 32A, 100A, 250A, 500A
Frequency range 45~65Hz
Input Output Switch value input 8-way passive main line contact DI input, internal supply DC24V power source
Relay output 4-way DO output, Contact capacity 250VAC/5A, 30VDC/5A
Analog output Output range 4~20mA, Programmable
Temperature input Measure range 0℃~100℃
Measurement accuracy Current ±1.0% (10%Ie~120%Ie)
Leakage current ±1.0% (5%Ise~100%Ise)
Voltage ±0.5% (20%Ue~150%Ue)
Frequency ±0.02Hz (45Hz~65Hz)
Power factor ±1.0% (-1~1)
Energy ±2.0%
Power ±2.0%
Communication Communication interface RS485 Photoelectric isolation interface
Communication protocol Modbus-RTU,1200~38400bps    Profibus-DP,9600~12Mbps
Electrical insulation Power frequency withstand voltage AC2kV/min~1mA Input-output-power source(GB/T 13729)
Insulation resistance >50MΩ(GB/T 13729)
Impact voltage 5kV(Peak), 1.2/50us(GB/T 13729)
Working environment Operating temperature -25℃~+70℃
Relative humidity 5%~95% No condensation
Storage temperature -30℃~+75℃
Electromagnetic Compatibility Surge (impact) immunity GB/T 17626.5-2008,Level3,IEC61000-4-2, level 4
Fast pulse group immunity GB/T 17626.4-2008,Level3,IEC61000-4-5, level 4
Electrostatic discharge immunity GB/T 17626.2-2006,Level3,IEC61000-4-4, level 4
Power frequency magnetic field immunity GB/T 17626.8-2006,Level3,IEC61000-4-8, level 4

KPM60F Low-voltage Motor Protection Controller Typical Wiring

KPM60 protection mode typical wiring diagram
KPM60 direct start mode typical wiring diagram
KPM60 bidirectional reversible mode typical wiring diagram