CPH smart harmonic suppression compensation module

CPH smart harmonic suppression compensation module


The CPH series smart harmonic suppression compensation module is based on low-voltage pure dry-type capacitors. It adopts the latest achievements in microcontroller technology, micro-sensors, micro-network technology and electrical appliance manufacturing technology. It integrates zero-point switching, protection, measurement, and online functions in one. It is a major breakthrough in the existing low-voltage reactive power compensation filtering technology. It is mainly used in reactive power compensation in very severe harmonics to ensure reliable operation and absorb and eliminate harmonics to a certain extent.




 

140x140
  • Smart harmonic suppression compensation module
  • Sync switch: >1 million times trouble-free switching, strong withstand voltage, current shock and anti-harmonic ability.
140x140
  • Real-time flexible monitoring : Real time monitoring and standard Modbus RTU communication. 
140x140
  • Perfect protection function: With current quick-break, overload, phase loss, three-phase unbalance protection, and over-voltage, under-voltage, loss of voltage, over-temperature, harmonic overrun and other protection types
  • Fault self-diagnosis: Once the slave self-diagnoses the fault, it will automatically exit immediately without affecting the normal operation of the system; if the master fails to exit, the slave will rebuild the online network.
140x140
  • Online function: <32 units online connection
    Flexible compensation method: Optional centralized and decentralized control

 

Model and size

Model

Specification

Outshape size(mm)

W

H

D

A

B

CPH-10/280/P7

CPH series 10kvar, 280V, 7%

192

440

360

180

250

CPH-15/280/P7

CPH series 15kvar, 280V, 7%

192

440

360

180

250

CPH-20/280/P7

CPH series 20kvar, 280V, 7%

192

440

360

180

250

CPH-10/300/P14

CPH series 10kvar, 300V, 14%

200

480

430

180

250

CPH-15/300/P14

CPH series 15kvar, 300V, 14%

200

480

430

180

250

CPH-20/300/P14

CPH series 20kvar, 300V, 14%

200

480

430

180

250

CPH-20/480/P7

CPH series 20kvar, 480V, 7%

192

440

360

180

250

CPH-30/480/P7

CPH series 30kvar, 480V, 7%

192

440

360

180

250

CPH-40/480/P7

CPH series 40kvar, 480V, 7%

200

480

430

180

250

CPH-20/525/P14

CPH series 20kvar, 525V, 14%

200

480

430

180

250

CPH-30/525/P14

CPH series 30kvar, 525V, 14%

200

480

430

180

250

CPH-40/525/P14

CPH series 40kvar, 525V, 14%

200

480

430

180

250

Technical parameters

Electrical performance

Working voltage

AC 400V (±10%)

Working type

3p3w, 3p4w

Rated frequency

50Hz (±3)

Reactance ratio

7%, 14%

Switching response time

≤200ms

Time interval

≥2s (configurable)

Reactive power compensation capability

≤40kvar (three-phase common compensation)
≤20kvar (single-phase split compensation)

Connection units

≥32pcs

Heat consumption

<3W(rated capacity)

Reliability parameter

Control accuracy

100%

Allowed switching times

≥1 million times

Capacitor capacity running time decay rate

<0.5% /year

Capacitor capacity switching attenuation rate

≤0.1% /million times

Annual failure rate

≤0.1%

Control feature

communication method

Modbus-RTU protocol, RS485 communication interface

Connection method

Network cables and electrical connections

Operating mode

Manual / Auto

Inrush

≤2.5 times the rated current

Cooling method

Forced air cooling

Structure feature

Installation method

Indoor, physical installation

Grounding method

Reliable connection via ground bolt

Dimensions

192x440x360 (mm) reactance rate is 7%

200x480x430 (mm) reactance is 14%

Environmental conditions

Ambient temperature

-25 °C- + 55 °C

Relative humidity

40 °C, 20-90%

Altitude

≤2000m

Implementation standards

In accordance with GB / T15576-2008


 

 